Yueqing Saip Electric Co., Ltd.

T Series Triple-output Switch Power Supply

T Series Triple-output Switch Power Supply
Product Detailed

1.T Series Triple-output Switch Power Supply
2,30W-100W Switch Power Supply
3,110/220VAC input switch power supply
4,CE

T Series Triple-output Switch Power Supply

Switch Power Supply, Switching Power Supply, Switch Mode Power Supply

 

Model

Performance

T-100C

 T-100D

CH1 CH1

CH2

CH3

CH1

CH2 

 CH3

 DC output voltage

5V 

15V

-5V

5V

12V 

 24V

 Output Voltage Tolerance (Note 2)

±2%

±6%

+2,-10% 

±2%

+6%

± 6%

Rated output current

10A

2.5A

1A

6A

2A

 2A

 Output Current Range

2 -12A

0.2 -2.5A

0.1 -1A

 2-12A 

0.1 -2A

0.2 -2A

 Ripple and noise (Note 3)

80mVp-p 

150mVp-p 

150mVp-p

80mVp-p 

150mVp-p

150mVp-p

 Into the line of stability (Note 4)

±0.5%

±1%

±1%

±0.5% 

±1%

±1%

Load stability (Note 5)

±1% 

±5%

±5%

±1%

±5%

±5%

 DC output power

100W

102W

Efficiency

80%

79%

 DC voltage adjustable range

CH1:+10,-5%

CH1:+10,-5%

 Input Voltage Range

85 ~ 132VAC/170 ~ 277VAC Selected by switch 47 ~ 63Hz;

 AC input current

2.5A /115V , 1.25A /230V

Inrush Current

Current 30A/115V 60A/230V cold start

 Leakage

<0.5mA/240VAC

Overload

 105% ~ 150% Type: FOLDBACK cut output  Recovery: recycle AC ON / OFF

 Over Voltage Protection

…… ... ...

Temperature Protection

…… ... ...

Temperature Coefficient

± 0.03%/ °C (0 ~ 50°C ) ON+5V OUTPUT

 Start, rise, hold time

200ms,50ms,16ms

 Earthquake resistance

10 ~ 500Hz, 2G 10min. / 1 cycle, duration 60 minutes, each axis

 Pressure of

Between input and output: 1.5KvAC, input and shell: 1.5KvAC, output and shell: 0.5KvAC

Isolation Resistance

 Input and output,  input and shell, shell and output: 500VDC/100M Ohms

 Temperature, humidity

-10°C~ + 60°C , 20% ~ 90%RH

 Storage temperature, temperature

-20°C ~ + 85°C ,10% ~ 95%RH

Dimensions

199*110*50mm

 Weight

0.83Kgs

 Safety Standards

To meet the UL1012 REQUIREMENT (NOT QPPLY FOR THE MARK)

 EMC Standards

 To meet the FCC PART15 J CONDUCT 10N CLASS A

Notes:

1 The above parameters test conditions are: 100-230VAC input, rated load, 25 °C 70% RH. Humidity. 
2 Tolerance: includes set up tolerance, line stability, load stability (Note 5).  

3 The ripple test: 20MHz with A12 "twisted pair, interrupted with 0.1uF & 47uF capacitor short-circuit. 
4 Into the line voltage stability test: full load into the line of the minimum voltage to maximum voltage.
5 Load stability test: the load from 0% to 100%, and other output at 60% rated load. 
6 The output of up to maximum current, but the overall load can not exceed the maximum output power.

 



Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.